Re: HP Data Protector

$
0
0

The pace where you would increase teh device time out is located at

 

Windows 2003

   Program FIles -> Omniback -> Config -> Server -> Options -> global

Windows 2008

   ProgramData -> Omniback -> Config -> Server -> Options -> global

 

UNIX

   /etc/opt/omni/server/options/global

 

Open the file in an editor, and find the line:

 

# SmWaitForDevice=WaitForInMinutes

# default: 60 minutes

 

Make a copy of the line, then, on one line remove the # sign and the 'space' that follows, and set the value to what you want to use, so, for example

 

SmWaitForDevice=120

# SmWaitForDevice=WaitForInMinutes

 

and save the file.  This will increase the timeout for devices to 2 hours.  At your earliest opportunity, stop and restart Data Protector