Re: Backup Session fails for only one filesystem with BMA timeout

$
0
0

Hi Bob,

 

Thanks. Parallaly we have opened a case with HP. They asked us to add few parameters related to keepalive you mentioned and we let the backup run as per schedule. Next day the scheduled backup ran sucessfully.

 

Now I have a query, We just did following changes on Cell manager in omnirc file.

 

OB2IPCKEEPALIVE=1
OB2IPCKEEPALIVETIME=900
OB2IPCKEEPALIVEINTERVAL=60
OB2INETTIMEOUT=600

 

and in addition to that the two variables we increased earlier in global file  i.e.

 

SmDaIdleTimeout = 300  

SmMaIdleTimeout= 340

 

Do we need to change any parameter on oVMS server as this is the server being backed up? If yes, will there be any performance issue since from oVMS server point of view?

 

Please advice.

 

Thanks & Regards,

 

Sandeep