Hi everyone.
We have configured DP 6.20 on a Windows Server 2003 R2 SP2. The client machines are HP-UX B.11.31.
We have not done any update patches on any machine before you start having these errors.
For weeks we have several errors that occur in the backup tool:
- This error occurs in some of our machines, and any new backup job that also create the same error.
"[Critical] From: OB2BAR_OMNISAP @ host" OMNISAP "Time: 06/22/14 14:09:34
Can not get configuration from the Cell Manager "ServerDP" with instance "SID"
[Major] From: OB2BAR_OMNISAP @ host "OMNISAP" Time: 06/22/14 14:09:34
Oracle backup file failed control.
"
We have reviewed a control file is created and the restore works properly but we would like to know what happened.
2. The other error occurs several times a week and the only solution we have found is to restart the server DP.
[Critical] From: OB2BAR_SAPBACK @ host "SID" Time: 06/23/14 5:17:17
Can not initialize OB2BAR Services (Interprocess communication problem.)
Can not init OB2BAR "Catalog not loaded, message # 7595 in set 11"
sh: 5466 Memory fault
[Critical] From: OB2BAR_SAPBACK @ host "SID" Time: 06/23/14 5:17:19
Can not initialize OB2BAR Services (Interprocess communication problem.)
Can not init OB2BAR "Catalog not loaded, message # 7595 in set 11"
sh: 5468 Memory fault
[Critical] From: OB2BAR_SAPBACK @ host "SID" Time: 06/23/14 5:17:21
Can not initialize OB2BAR Services (Interprocess communication problem.)
Can not init OB2BAR "Catalog not loaded, message # 7595 in set 11"
sh: 5470 Memory fault
[Critical] From: OB2BAR_SAPBACK @ host "SID" Time: 06/23/14 5:17:23
Can not initialize OB2BAR Services (Interprocess communication problem.)
Can not init OB2BAR "Catalog not loaded, message # 7595 in set 11"
sh: 5472 Memory fault
[Critical] From: OB2BAR_SAPBACK @ host "SID" Time: 06/23/14 5:17:25
Can not initialize OB2BAR Services (Interprocess communication problem.)
Can not init OB2BAR "Catalog not loaded, message # 7595 in set 11"
sh: 5558 Memory fault
[Critical] From: OB2BAR_SAPBACK @ host "SID" Time: 06/23/14 5:17:27
Can not initialize OB2BAR Services (Interprocess communication problem.)
Can not init OB2BAR "Catalog not loaded, message # 7595 in set 11"
sh: 5647 Memory fault
[Critical] From: OB2BAR_SAPBACK @ host "SID" Time: 06/23/14 5:17:29
Can not initialize OB2BAR Services (Interprocess communication problem.)
Can not init OB2BAR "Catalog not loaded, message # 7595 in set 11"
sh: 5658 Memory fault
I hope your help. Thank you for everything