IPC Read Error System error: [232] - ECC Issue?

$
0
0

Since we've enabled ECC many sessions fail with IPC errors. Have you seen similar errors and how could the issue be fixed?

 

[Major] From: BSM@host.hp.com "E2k10_DAG01_Logs"  Time: 21.03.2013 08:34:10[61:3003]Lost connection to OB2BAR Backup DA named "ERROR" on host host.hp.com.

Ipc subsystem reports: "IPC Read Error System error: [232] Connection reset by peer"

 

The client's Windows log reveals OpenSSL errrors:

Faulting application name: vssbar.exe, version: 6.20.370.0, time stamp: 0x4d68150e

Faulting module name: ssleay32.dll, version: 0.0.0.0, time stamp: 0x4c349015

 

The customer runs DP 6.21 including latest patches.

 

The omnirc on Cell Manager and all clients includes:

OB2IPCKEEPALIVE=1

OB2SHMIPC=0

OB2IPCKEEPALIVETIME=900

OB2IPCKEEPALIVEINTERVAL=60

OB2INETTIMEOUT=10

 

Regards,

Michael