Re: HP-UX: Move DB40 from DP 6.0 to DP 7.0

$
0
0

I got the Itanium 11.31 system installed with 6.20 and migrated the IDB to the new system (and it works OK - I'm taking backups and can see all the old media). However, the upgrade to 7.0 (omnisetup.sh) failed completely saying that the databasae version is 6.00 and aborted the install:

 

...

NOTE:    Data Protector database version A.06.00 found.

ERROR:   Unknown/unsupported Data Protector database version detected

         on system.

         Data Protector software can not function properly with this

         database. Refer to documentation for manual upgrade

         procedure after the installation.

ERROR:   The "checkinstall" script for "DATA-PROTECTOR" failed (exit

         code "1"). The script location was

         "/var/tmp/BAA012181/catalog/DATA-PROTECTOR/pfiles/checkinstall".

...

 

The GUI, omnidb -version, all report version 6.20, and the database was converted from 32 to 64 bit successfully during the 6.0 to 6.20 migration. But when I list the version files:

 

# cat /var/opt/omni/server/db40/datafiles/catalog/version.txt

HP OpenView OmniBack II A.06.00hqqaddev /root

# cat /var/opt/omni/server/db40/datafiles/cdb/version.txt

HP OpenView OmniBack II A.06.00hqqaddev /root

# cat /var/opt/omni/server/db40/datafiles/mmdb/version.txt

HP OpenView OmniBack II A.06.00hqqaddev /root

 

 

Any thoughts?